Venturi throat

Insertion type Venturi tube is a classic Venturi tube with a smaller diameter inserted into the center of a circular pipeline. The difference between the static pressure of the front straight pipe and the throat of the insertion tube is measured to determine the flow rate, which can be used for gas flow rates with larger diameters (such as blast furnace gas, flue gas, etc.).

LPG nozzle

LGP nozzle, also known as standard nozzle. Its design, manufacturing, and use comply with the provisions of international standards ISO5167 or GB/T2624. Due to its arc-shaped inlet and cylindrical shape with a certain length, it has good wear resistance and corrosion resistance, and is commonly used for measuring the flow rate of liquids and gases under high temperature and pressure.

Annubar Flow element Pitot Tubes Flowmeter

The Pitot tube flowmeter is a double layered hollow manifold tube bent at a right angle, with multiple pressure tapping holes, capable of measuring both total fluid pressure and static pressure simultaneously. Used in conjunction with differential pressure transmitters and flow display devices. It is widely used in the production processes of industries such as petrochemicals, metallurgy, power plants, electricity, and textiles to measure the flow rate of fluids such as gases, liquids, steam, water, and air volume.

Intelligent electromagnetic flowmeter

SCD type electromagnetic flowmeter: used to measure the volume flow of conductive liquid and slurry in closed pipelines. Applicable to: chemical industry, electric power, metallurgy, petroleum, water supply and drainage, papermaking, medicine, food and other departments.

Sanitary electromagnetic flowmeter

SCD type electromagnetic flowmeter is used to measure the volume flow of conductive liquid and slurry in closed pipelines. It is suitable for chemical industry, electric power, metallurgy, petroleum, water supply and drainage, papermaking, medicine, food and other departments.

Ultrasonic level gauge

When the ultrasonic level meter works, the high-frequency pulse sound wave is emitted by the transducer (probe), and the surface of the measured object (water surface) is reflected, and the reflected echo is received by the same transducer (probe) and converted into an electrical signal. The time between the transmission and reception of the pulse (the movement time of the sound wave) is proportional to the distance from the transducer to the surface of the object, and the height of the liquid level or material level is calculated.
< 1234...12 >

SAF Coolest v1.3.1.2 设置面板DNZSD-ZEAH-UXZSE-ZVQ

图片ALT信息: Chuanzhi Technology
违禁词: First, best, first-class, leading, unique, king, leader, leader, extreme,

无数据提示

Sorry, the current column is being updated, please look forward to it!

You can view other columns or returnHome Page

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用